Swirls from the Cylinder Machines

Created by SVE Labs, Modified on Tue, 30 Jan, 2024 at 4:55 PM by SVE Labs

Things to check: 


- Finer Air Regulator set to 18 PSI, time at 90 Seconds 


- Polisher Air Regulator set to 24 PSI, time at 240 Seconds 


- Polish Quality: Check Consistency, discoloration, Etc. Replace polish. 


- Change Polish Pad Roll to eliminate the possibility of a bad sample 

        (Make sure the batch # is different)


- Perform Lens Curve Calibration on 2G(s). Poly Lenses should fine out within 20 seconds      on high. 


- Verify Pattern Calibration on Cylinder Machines 


- Verify Pin Pressure on Cylinder Machines 